Olectra K9 Electric Bus battery recycling in Atlanta, Georgia
Atlanta, Georgia is a diagnostics site: Olectra K9 Electric Bus packs arrive here from intake yards for module-level capacity, resistance and impedance testing, which decides reuse or refining.
Pack value at 80% SOH
10,377 USD
Hybrid Split
Second-life share
56%
At 80% SOH
Site capacity
22,000 TPA
Cell Grading & Diagnostics
Cities served
0
From Atlanta, Georgia
Where a Olectra K9 Electric Bus pack goes from Atlanta, Georgia
- 1
Collected via Detroit, Michigan
Whole packs enter the network at Detroit — Michigan Closed-Loop Plant, 961 km away, where they are weighed and de-energised.
- 2
Module grading at Atlanta, Georgia
All 22 modules are tested for capacity, DC resistance and impedance, then assigned grade A to D.
- 3
Second life at Gothenburg, Sweden
At 80% SOH about 56% of the pack qualifies for reuse and goes to Gothenburg — Nordic Second-Life Campus (7,243 km). Excellent — long calendar life makes LFP the preferred feedstock for stationary BESS repurposing.
- 4
Refined at Reno, Nevada
Remaining modules are shredded to black mass and refined at Reno — Nevada Hydrometallurgy Refinery, 3,203 km away.
| Stage | Facility | Distance |
|---|---|---|
| Nearest intake yard | Detroit — Michigan Closed-Loop Plant | 961 km |
| Nearest second-life works | Gothenburg — Nordic Second-Life Campus | 7,243 km |
| Nearest refinery | Reno — Nevada Hydrometallurgy Refinery | 3,203 km |
Faster option
Inside the Olectra K9 Electric Bus battery
The Olectra K9 Electric Bus (2021) carries a 324 kWh LFP Prismatic (LiFePO4) pack with 22 modules at 620 V, weighing roughly 2398 kg. Cobalt-free prismatic chemistry dominant in Indian passenger EVs and commercial fleets. Low black mass value, exceptional second-life economics.
| Service year | SOH | Grade | Value |
|---|---|---|---|
| Year 2 | 95.5% | A — BESS ready | USD 16,875 |
| Year 4 | 92.4% | A — BESS ready | USD 16,339 |
| Year 6 | 89.3% | A — BESS ready | USD 15,803 |
| Year 8 | 86.2% | A — BESS ready | USD 15,034 |
| Year 10 | 83.1% | B — Second life | USD 12,605 |
What the chemistry means here
How it ages
LFP fades slowly and fairly linearly for most of its life. Capacity loss is driven mainly by lithium inventory being locked up in the SEI layer on the graphite anode, while the cathode structure stays largely intact.
Thermal behaviour
LFP's olivine cathode holds its oxygen tightly, so thermal runaway typically starts at higher temperatures than nickel-rich cells and releases noticeably less heat. It is not inert: a failing LFP cell still vents flammable electrolyte vapour and hydrogen, and large prismatic cans store a lot of energy in one place.
Handling LFP Prismatic
Collecting a Olectra K9 Electric Bus pack
324 kWh, 22 modules, about 2398 kg — this is how the Atlanta, Georgia team plans the job.

Removal
Roof- or floor-mounted packs are lifted by crane or gantry with the OEM lifting frame, one string at a time.
Packaging
Packs travel as individual heavy crates on flatbed or curtain-side trailers with load restraint rated for the mass.
Consolidation
Bus packs are collected per depot and per retirement window, usually a full trailer per visit.
Before the truck arrives
- Confirm crane or gantry access and lifting frame availability
- Isolate each pack string and record its voltage
- Share pack-string serials against the bus fleet number
- Plan collection around depot operating hours
Atlanta, Georgia site notes
- Fleet depots across the south-east can book consolidated pickups to share transport cost.
- Send serial lists so grading reports map directly to your asset records.
- Damaged or recalled packs must be declared so they ship under the correct DOT provisions.
- Shrink-wrap pallets and label them with the correct UN numbers before collection.
What this pack yields
lithium
24.03 kg
nickel
0 kg
cobalt
0 kg
manganese
0 kg
copper
72.67 kg
aluminium
86.74 kg
Refining-route estimate at 80% SOH. Measured module health on the bench sets the final split.
Rules in United States
EPA universal waste rules, DOT hazardous materials regulations and state programmes
Regulator: EPA, DOT PHMSA and state environmental agencies
The centre operates under Georgia Environmental Protection Division requirements and manages spent lithium-ion batteries under the US EPA universal waste framework where applicable. Transport follows US DOT hazardous materials rules for lithium batteries.
Olectra K9 Electric Bus in Atlanta, Georgia: common questions
Can I drop off a Olectra K9 Electric Bus battery at Atlanta, Georgia?
Atlanta, Georgia is a cell grading & diagnostics and does not accept whole packs from customers. Book a collection and the pack enters the network at Detroit, Michigan, 961 km away.
What happens to Olectra K9 Electric Bus modules after Atlanta, Georgia?
Collected via Detroit, Michigan, then Module grading at Atlanta, Georgia, then Second life at Gothenburg, Sweden, then Refined at Reno, Nevada. At 80% SOH roughly 56% of the pack goes to second life and the rest is refined.
How should a Olectra K9 Electric Bus pack be prepared for pickup?
Confirm crane or gantry access and lifting frame availability. Isolate each pack string and record its voltage. Share pack-string serials against the bus fleet number. Plan collection around depot operating hours.
Which rules apply to Olectra K9 Electric Bus recycling in United States?
EPA universal waste rules, DOT hazardous materials regulations and state programmes, overseen by EPA, DOT PHMSA and state environmental agencies. Shipments follow DOT PHMSA 49 CFR requirements, with damaged or defective batteries under stricter special permits and packaging.
Olectra K9 Electric Bus at other sites
Other bus packs at Atlanta, Georgia
Retiring Olectra K9 Electric Bus packs near Atlanta, Georgia?
Share pack counts and condition. The despatch desk confirms a collection window within one working day and sends the right packaging.