EVBatteryRecycling
Cross-border intakeTwo-Wheeler · LMO Pouch

Greaves Ampere Magnus battery recycling in Detroit, Michigan

The Greaves Ampere Magnus is not sold in this market, so packs reach Detroit, Michigan through importers, research and test fleets or cross-border consolidation. They are accepted as whole packs, with extra checks on documentation and transboundary paperwork.

Pack value at 80% SOH

99 USD

Hybrid Split

Second-life share

47%

At 80% SOH

Site capacity

40,000 TPA

Integrated Recovery Campus

Cities served

10

From Detroit, Michigan

Greaves Ampere Magnus pack data
Route

Where a Greaves Ampere Magnus pack goes from Detroit, Michigan

  1. 1

    Intake at Detroit, Michigan

    Packs travel in UN-approved steel or plastic cages with non-conductive dividers, typically dozens per cage. Each pack is weighed, photographed and discharged below 30% state of charge.

  2. 2

    Graded at Atlanta, Georgia

    Modules travel 961 km to Atlanta — Georgia Grading Centre for capacity, resistance and impedance testing across all 2 modules.

  3. 3

    Second life at Gothenburg, Sweden

    At 80% SOH about 47% of the pack qualifies for reuse and goes to Gothenburg — Nordic Second-Life Campus (6,413 km). Limited — accelerated manganese dissolution caps second-life warranty terms at 36 months.

  4. 4

    Refined at Reno, Nevada

    Remaining modules are shredded to black mass and refined at Reno — Nevada Hydrometallurgy Refinery, 3,080 km away.

StageFacilityDistance
Nearest grading benchAtlanta — Georgia Grading Centre961 km
Nearest second-life worksGothenburg — Nordic Second-Life Campus6,413 km
Nearest refineryReno — Nevada Hydrometallurgy Refinery3,080 km
Straight-line distances from Detroit, Michigan to the next facilities in the network.

Faster option

The closest direct intake sites for Greaves Ampere Magnus packs are Narela, Delhi (11,843 km) and Unnao, Uttar Pradesh (12,172 km).
The pack

Inside the Greaves Ampere Magnus battery

The Greaves Ampere Magnus (2021) carries a 3.4 kWh LMO / LMO-NMC Pouch pack with 2 modules at 60 V, weighing roughly 28 kg. Legacy manganese-rich pouch packs common in early two- and three-wheeler fleets across South Asia.

Service yearSOHGradeValue
Year 295.5%A — BESS readyUSD 123
Year 491.2%A — BESS readyUSD 119
Year 686.9%A — BESS readyUSD 114
Year 882.6%B — Second lifeUSD 104
Year 1078.3%B — Second lifeUSD 96
Modelled state of health and residual value for the Greaves Ampere Magnus pack.
LMO Pouch

What the chemistry means here

01

How it ages

LMO's weak point is manganese dissolution, which speeds up at elevated temperature and damages the anode. Packs that lived in hot climates without active cooling typically fade faster.

02

Thermal behaviour

Manganese spinel is more thermally stable than nickel-rich cathodes, but blended LMO-NMC pouch cells still vent flammable gas when abused, and older packs may have weaker protection electronics.

Handling LMO Pouch

Many LMO packs come from early two- and three-wheelers and informal service channels. Expect missing documentation, check for prior repair and quarantine anything with swelling or corrosion.
Two-Wheeler handling

Collecting a Greaves Ampere Magnus pack

3.4 kWh, 2 modules, about 28 kg — this is how the Detroit, Michigan team plans the job.

Removing a two-wheeler EV battery pack for recycling
01

Removal

Removable packs are unclipped by hand; fixed packs are removed at the dealer bench with the frame supported.

02

Packaging

Packs travel in UN-approved steel or plastic cages with non-conductive dividers, typically dozens per cage.

03

Consolidation

Dealer and swap-station returns are aggregated at a single point so one collection clears many units.

Before the truck arrives

  • Tape terminals and connectors on every pack
  • Separate swollen or dropped packs into their own container
  • Record serials in a single list per cage
  • Store below 30% charge away from charging racks

Detroit, Michigan site notes

  • Send architecture drawings or a disassembly note with prototype packs so the right procedure is prepared.
  • Engineering centres can book recurring collections for validation and test waste.
  • Damaged, defective or recalled units must be declared so they ship under the correct DOT provisions.
  • Truck and large commercial packs need advance notice so rigging and crew are scheduled.
Recovery

What this pack yields

lithium

0.24 kg

nickel

0.51 kg

cobalt

0.07 kg

manganese

1.49 kg

copper

0.94 kg

aluminium

1.06 kg

Refining-route estimate at 80% SOH. Measured module health on the bench sets the final split.

Compliance

Rules in United States

EPA universal waste rules, DOT hazardous materials regulations and state programmes

Regulator: EPA, DOT PHMSA and state environmental agencies

The campus operates under permits administered by Michigan's Department of Environment, Great Lakes, and Energy (EGLE), and manages spent lithium-ion batteries under the US EPA universal waste framework where it applies. Transport follows US DOT hazardous materials regulations for lithium batteries, including the separate provisions for damaged, defective or recalled cells.

FAQ

Greaves Ampere Magnus in Detroit, Michigan: common questions

Can I drop off a Greaves Ampere Magnus battery at Detroit, Michigan?

Yes, by appointment. Detroit — Michigan Closed-Loop Plant accepts whole Greaves Ampere Magnus packs; book a collection or a drop-off slot so the site can prepare packaging and paperwork.

What happens to Greaves Ampere Magnus modules after Detroit, Michigan?

Intake at Detroit, Michigan, then Graded at Atlanta, Georgia, then Second life at Gothenburg, Sweden, then Refined at Reno, Nevada. At 80% SOH roughly 47% of the pack goes to second life and the rest is refined.

How should a Greaves Ampere Magnus pack be prepared for pickup?

Tape terminals and connectors on every pack. Separate swollen or dropped packs into their own container. Record serials in a single list per cage. Store below 30% charge away from charging racks.

Which rules apply to Greaves Ampere Magnus recycling in United States?

EPA universal waste rules, DOT hazardous materials regulations and state programmes, overseen by EPA, DOT PHMSA and state environmental agencies. Shipments follow DOT PHMSA 49 CFR requirements, with damaged or defective batteries under stricter special permits and packaging.

Coverage

Cities collected by Detroit, Michigan

Retiring Greaves Ampere Magnus packs near Detroit, Michigan?

Share pack counts and condition. The despatch desk confirms a collection window within one working day and sends the right packaging.